Terralux TLM-R16C Bedienungsanleitung Seite 4

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 6
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 3
www.terraluxilluminaon.com
TerraLUX TLM-R16C Product Specicaon (05/03/2013) Subject to change without noce 4
TESTS AND CERTIFICATIONS
Product Safety Cercaons • UL Standard 1993: Self Ballasted Lamps and Lamp Adaptors
• UL Standard 8750: LED Light Sources for Use In Lighng Products
• CSA C22.2 No. 1993-09: Self Ballasted Lamps and Lamp Adaptors
Radio Frequency Emissions •FCC Part 15, Unintenonal Radiators Class B.
Sec 107, Conducted Emissions - 0.15MHz – 30MHz
Sec 109, Radiated Emissions - 30 MHz – 8000MHz
•Industry Canada Noce ICES-003: Class B Digital Apparatus
Reducon of Hazardous Substances
(RoHS)
• European Council Direcve 2002/95/EC, (including amendments 2005/618/EC,
2005/717/EC and 2005/747/EC) on the restricon of certain hazardous substances in
electrical and electronic equipment.
Electro-Stac Discharge •± 4kV and ± 6kV contact discharge
•±8kV and ± 10kV air gap discharges
Power Factor 0.92 @ 12 V AC (high mode)
Shock Operang - 82 G peak, 2 ms; Half sine, 1 shock per second 20 shocks per axis, both di-
recons – total 120 shocks
Non-Operang - 120 G peak., 2 ms, Half sine, 1 shock/second, 3 shocks per axis, both
direcons total of 18 shocks
40 G Faired Square wave w/ velocity change of 62 in/sec. 1 shock per axis, both direc-
ons – total of 6 shocks
Drop Test - Drop from a distance of 1 meter onto a non-resilient test oor. The test
surfaces shall be the face, two opposing sides, the base, and two opposing top corners.
Operaon is to be checked aer each impact.
Drop Test
Vibraon
Operang - Random PSD Spectrum G, 1.0G RMS, 10-2000 Hz. 30 minutes per axis 3-
500 Hz., 0.50 g peak, swept sine @ ½ octave/min per axis
Non-Operang - Random PSD, 5 G RMS, 15 minutes per axis
5-500-5 Hz, 1.0 g peak, Swept Sine @ ½ Octave per minute, per axis.
Shipping / Transit Internaonal Safe Transit Associaon (ISTA) Project 2A.
Operang Temperature -40°C to +55°C, 0 to 95% R.H. / 157 hr.
Storage Temperature -40°C to +85°C / 60 hr. followed by 20°C to 85°C, 5 to 95% R.H. / 80 hr.
Lumen Maintenance L70 =60,000hr per IES TM-21-11 (Based on LED Manufacturer’s measurement per IES
LM-80-08 @ 10.000hrs).
Long Term Operaon MBTF = 62,000 hours
Input Voltage Range 9.6—14.4 V AC / 12—14.4 V DC
Dimming Meets NEMA Standards Publicaon SSL 6-2010, Solid State Lighng for Incandescent
Replacement—Dimming. Specically the upper and lower limits of light output vs. dim-
mer posion and that the dimming is strictly monotonic. When connected to a variety
of electronic dimmer/transformer combinaons fell within the upper and lower limits of
the light output curve dened by NEMA